DG-P

Load Cells & Sensors
DG-P
On-BoardOn-Board
The pressure transducer features  great reliability, small size, high accuracy, light weight and wide pressure range. It can be applied in many fields where measurement of pressure is required.
 
get a quote

Part Number

Capacity / Code
50 bar / 140-0108
250 bar / 140-0062
500 bar / 140-0110
1000 bar / 140-0111

 

Circuit

Size

Product Features

Cable length: 5000 mm
Ingress Protection: IP67
Accuracy: N.A.
Capacity:
Load: 50-250-500-1000 bar
Material: Steel
Number of verification intervals: N.A.
Output:
50 bar:  1.0mV/V± 0.1
250 - 1000 bar:  2.0mV/V± 0.1
Zero Balance: ± 2 %F.S.
Error:
Combined: 0.5 %F.S.
Repeatability: -
Creep: -
Temperature Effect:
On output: 0.009 %F.S./°C
On zero: 0.009 %F.S./°C
Impedance:
Input: 350 ± 50 Ω
Output: 350 ± 10 Ω
Insulation: ≥3000 / 50VDC MΩ (min)
Excitation:
Recommended: 10 V
Maximum: 15 V
Temperature Range:
Compensated: 20 ÷ 70 °C
Operating: -10 ÷ 80 °C
Overload:
Safe: 120 %F.S.
Ultimate: 150 %F.S.
Load cell verification interval: N.A.
Cable diameter: Ø5.5 mm (max)
Cable type: Shielded cable 4x0.35

Download Technical Sheet