DG-P

Celle Di Carico
DG-P
On-FarmOn-Farm
Feed MixerFeed Mixer
BiogasBiogas
The pressure transducer features  great reliability, small size, high accuracy, light weight and wide pressure range. It can be applied in many fields where measurement of pressure is required.
 
Richiedo offerta Desidero saperne di più

Part Number

Capacity / Code
50 bar / 140-0108
250 bar / 140-0062
500 bar / 140-0110
1000 bar / 140-0111

 

Circuit

Size

Caratteristiche Prodotto

Capacity:
Load: 50-250-500-1000 bar
Accuracy: N.A.
Number of verification intervals: N.A.
Load cell verification interval: N.A.
Output:
50 bar:  1.0mV/V± 0.1
250 - 1000 bar:  2.0mV/V± 0.1
Zero Balance: ± 2 %F.S.
Error:
Combined: 0.5 %F.S.
Repeatability: -
Creep: -
Temperature Effect:
On output: 0.009 %F.S./°C
On zero: 0.009 %F.S./°C
Impedance:
Input: 350 ± 50 Ω
Output: 350 ± 10 Ω
Insulation: ≥3000 / 50VDC MΩ (min)
Excitation:
Recommended: 10 V
Maximum: 15 V
Temperature Range:
Compensated: 20 ÷ 70 °C
Operating: -10 ÷ 80 °C
Overload:
Safe: 120 %F.S.
Ultimate: 150 %F.S.
Protezione: IP67
Material: Steel
Cable length: 5000 mm
Cable diameter: Ø5.5 mm (max)
Cable type: Shielded cable 4x0.35

Download Technical Sheet