DG-SPL

Load Cells & Sensors
DG-SPL
The off-center load cells  are suitable for use in a wide range of packaging machinery, low capacity scales, bench scales, checkweighers and general process weighing and of course standard weighing platforms. get a quote

Part Number

Capacity / Code
5kg / 140-0114
10kg / 140-0084
15kg / 140-0055
20kg / 140-0142
30kg / 140-0056
50kg / 140-0057

 

Circuit

Size

Mounting

Product Features

Cable length: 3000 mm
Ingress Protection:  IP65
Accuracy:
Class: C3
Dimensions:
Platform: 300 X 350 mm
Capacity:
Load: 5-10-15-20-30-50 kg
Material: ALUMINIUM
Number of verification intervals:
Maximum: 3000 nmax
Relative Vmin: 6000 Y
Output:
Rated: 2.0 ± 1% mV/V
Zero Balance: ± 2 %F.S.
Error:
Combined: 0.02 %F.S.
Repeatability: 0.02 %F.S.
Creep: 0.03 %F.S. / 30min.
Temperature Effect:
On output: 0.025 %F.S./10°C
On zero: 0.025 %F.S./10°C
Impedance:
Input: 410 ± 15 Ω
Output: 350 ± 4 Ω
Insulation: 2000/50VDC MΩ
Excitation:
Recommended: 10V
Maximum: 20V
Temperature Range:
Compensated: -10 ÷ 40 °C
Operating: -20 ÷ 70 °C
Overload:
Safe: 150 %F.S.
Ultimate: 200 %F.S.
Cable diameter: Ø5.5 mm (max)
Cable type: Shielded cable 4x0.35

Download Technical Sheet

Siglacom - Internet Partner