DG-SP 6

Load Cells & Sensors
DG-SP 6
The off-center load cells  are suitable for use in a wide range of packaging machinery, low capacity scales, bench scales, checkweighers and general process weighing and of course standard weighing platforms. get a quote

Part Number

Capacity / Code

100 kg / 140-0153
250 kg / 140-0155
750 kg / 140-0157
2000 kg / 140-0158

Circuit

Size

Mounting

Product Features

Cable length: 3000mm
Ingress Protection: IP65
Accuracy:
Class: C3
Dimensions:
Platform (Range 750kg-2000kg): 1200x1200mm
Platform (Range 100kg-250kg): 800x1200mm
 
Capacity: 100-250-750-2000 kg
Material: ANODIZED ALUMINIUM
Number of verification intervals:
Maximum: 3000 nmax
Output:
Rated: 2.0 ± 10% mV/V
Zero Balance: 2.0 %F.S.
Error:
Combined: 0.02 %F.S.
Repeatability: 0.02 %F.S.
Creep: 0.03 %F.S. / 30min.
Temperature Effect:
On output: 0.025 %F.S./10°C
On zero: 0.025 %F.S./10°C
Impedance:
Input: 410 ± 15 Ω
Output: 350 ± 4 Ω
Insulation: 2000(50VDC) MΩ (min)
Excitation:
Recommended: 5 ~ 10V (DC)
Maximum: 15V (DC)
Temperature Range:
Compensated: -10 ~ +40 °C
Operating: -20 ~ +60 °C
Overload:
Safe: 150 %F.S.
Ultimate: 300 %F.S.
Load cell verification interval:
Maximum: Emax/7000 Vmin
Cable diameter: Ø4mm (max)
Cable type: Shielded cable 4x0.12

Download Technical Sheet